GE Critical Power Products

The TLE Series UPS is a super reliable and highly efficient uninterruptible power supply designed for a wide range of mission-critical applications such as server rooms, data centers, data closets, telecommunications, medical/healthcare, commercial and industrial critical processes where power quality and up-time is of absolute necessity.

TLE Series UPS is designed using a double conversion methodology employing a true on-line VFI (voltage frequency independent) technology. The IGBT front end converter provides very low input current THD (total harmonics distortion) and near unity input power factor to minimize the input feeder size. The transformerless IGBT Inverter design ensures near perfect voltage sign wave with very low voltage distortion and very fast transient response to high crest factor or 100% step loads.

3-level IGBT design increases efficiency over 2-level legacy UPS design. The efficiency remains high whether the UPS is partially or fully loaded. The efficiency ranges from 95.5% in double conversion mode to 98.9% in Eco mode.

Modular design allows for scalable topology by adding power modules or paralleling multiple UPS cassis to provide for higher capacity or redundancy

GE UPS Details

Three Phase UPS Systems

LP33 Series II

LP33 Series II
208VAC Transformerless UPS

Topology:

  • Multi Mode UPS – DC & EM
  • 208/120V, 3ph 4w input/output
  • 15, 20, 30, 50, 60, 80, 100kva
  • Output PF at 0.90
  • PWM IGBT Rectifier & Inverter
  • 4-6msec transfer EcoMode
  • Fully Rated Bypass Static Switch

Features/Options:

  • RPA Paralleling/ 4 units max
  • SBM Battery Monitoring
  • Remote Connectivity via SNMP, BMS, RASP
  • Seismic Certifications
  • Matching Ext Batt Cabinets
  • Matching Ext MBP Cabinets
  • Matching Inp Xfmr Cabinets
  • Top Entry Sidecar
  • Seismic Certifications

Key Specifications:

  • Wide Input Voltage, 166-240V L-L
  • Wide Input Frequency, 54-66 Hz
  • Low Acoustic Noise, 50-65dbA
  • Input Current THD < 10%
  • Output Voltage THD < 2%
  • Input PF > 0.98
  • Up to 98% Efficient
  • 150% Overload for 1 min

TLE MidPower Series TLE MidPower Series TLE MidPower Series

TLE MidPower Series
50-150kVA @ 480VAC

Topology:

  • Transformerless, 3-Level IGBT
  • 480/277VAC, 3phase 4wire
  • Scalable using 50kW Power Blocks
  • Configurable up to 3x50kW or 3x40kW
  • Unity (1.0) Output PF
  • Up to 96% Efficiency ; 98% EcoMode
  • Parallel up to 6 units in RPA
  • No internal redundancy
  • Ventilation Front to Top
  • Only Front Access Needed
  • Connections Front/Bottom
  • Matching Battery Cabinets
  • Matching MBP Cabinets
  • Matching 4x2 Cabinet
  • Matching Distribution Cabinet
  • Blackbox Diagnostics
  • 2 Year Warranty

TLE Series

TLE Series
480VAC Transformerless UPS

Topology/ Key Specifications:

  • Multi Mode UPS, DC & EM
  • 480/277V 3ph, 3w or 4w
  • 225, 250, 400, 500, 750, 1000kVA
  • Unity (1.0) Output PF
  • High 0.99 Input PF
  • Less than 5% ICHD
  • 3-Level IGBT Rectifier & Inverter
  • Bypass Inductor
  • Fully Rated Bypass Static Switch
  • Small Industry Footprint
  • Touch Screen Color Display
  • Fast MTTR/250kw Power Blocks
  • Internal MBP Capability

Features/Options:

  • Up to 97% Dbl Conv Eff
  • Up to 99% eBoost Eff
  • Multi-Module Designs:
  • RPA Parallel / 6 max
  • Catcher UPS
  • 2N Systems
  • Iso Ring Bus
  • I/O Cable Saver Feature
  • SBM Battery Monitoring
  • Remote Connectivity via SNMP, BMS, RASP
  • Matching Battery Cabinets
  • Matching Ext MBP Cabinets
  • Matching Ext 4x2 Cabinets

Key Specifications:

  • Wide Input Voltage, 166-240V L-L
  • Wide Input Frequency, 54-66 Hz
  • Low Acoustic Noise, 50-65dbA
  • Input Current THD < 10%
  • Output Voltage THD < 2%
  • Input PF > 0.98
  • Up to 98% Efficient
  • 150% Overload for 1 min

SG Series

SG Series
480VAC Iso-Transformer UPS

Topology/ Key Specifications:

  • Single Mode UPS, Dbl Conv
  • Output Isolation ZigZag Xfmr
  • 480/277V 3ph 3w/4w input & output
  • 10, 20, 30, 40, 50, 80, 100, 120, 150kVA (at 0.8 OPF)
  • 225, 300kva (at 0.90 OPF) with eBoost capability
  • Less than 7% ICHD (w/filter)
  • 0.96 input pf
  • 6-Pulse Thyristor Bridge Rectifier
  • 2-Level PWM IGBT Inverter
  • Fully Rated Bypass Static Switch
  • Internal MBP Capability

Features/Options:

  • Up to 95% Dbl Conv Eff
  • Up to 99% eBoost Eff
  • Multi-Module Designs:
  • RPA Parallel / 6 max
  • Catcher UPS
  • 2N Systems
  • I/O Cable Saver Feature
  • SBM Battery Monitoring
  • Remote Connectivity via SNMP, BMS, RASP
  • Seismic Certifications
  • Matching Battery Cabinets
  • Matching Ext MBP Cabinets
  • Matching Ext 4x2 Cabinets
  • Seismic Certifications

Key Specifications:

  • Wide Input Voltage, 166-240V L-L
  • Wide Input Frequency, 54-66 Hz
  • Low Acoustic Noise, 50-65dbA
  • Input Current THD < 10%
  • Output Voltage THD < 2%
  • Input PF > 0.98
  • Up to 98% Efficient
  • 150% Overload for 1 min

site map - For information about this site, please contact TryEZ, LLC. a marketing, advertising and website design company.
toshiba Backup power UPS eaton single phase and 3 phase ups Power distribution PDU Static Transfer Switches water leak detection emergency lighting portable ac ups Micro-Modular Data Centers energy Surge Suppression data center hvac HVAC Variable Frequency Drives cerus Smart Starters dehumidifier power conditioners, and voltage regulators UPS - Uninterruptible Power Supply DC power systems